Chapter 296-104. Board of boiler rules—Substantive.  


Section 296-104-001. Administration—To what do these rules apply?
Section 296-104-010. Administration—What are the definitions of terms used in this chapter?
Section 296-104-015. Administration—When and where are the board meetings held?
Section 296-104-017. Administration—How are rules affected if other rules are invalidated?
Section 296-104-018. Administration—Interpretation of rules—Appeal rights—Hearings.
Section 296-104-019. Administration—How are Washington state specials and extensions of inspection frequencies for boilers and pressure vessels obtained?
Section 296-104-020. Administration—What are the filing requirements for boilers and unfired pressure vessels before their installation/reinstallation?
Section 296-104-021. Administration—What is the registration requirement for new standard boilers and unfired pressure vessels?
Section 296-104-025. Administration—What are the notification and reporting requirements following an accident involving a boiler or pressure vessel?
Section 296-104-030. Administration—What is the penalty for operation of unsafe boilers or unfired pressure vessels?
Section 296-104-035. Administration—What are conflicts of interest for inspectors?
Section 296-104-040. Administration—When should inspectors submit inspection reports and on what forms?
Section 296-104-045. Administration—What are the insurance companies' responsibilities?
Section 296-104-050. Administration—What are the requirements for a boiler inspector?
Section 296-104-060. Administration—When shall an inspectors' Washington state commission be issued, suspended, or revoked?
Section 296-104-065. Administration—How should an inspector obtain a Washington state commission?
Section 296-104-100. Inspection—How often must boilers and unfired pressure vessels be inspected?
Section 296-104-102. Inspection—What are the standards for in-service inspection?
Section 296-104-105. Inspection—How much time is required for notification of an internal inspection?
Section 296-104-110. Inspection—What will be done when boilers or unfired pressure vessels are deemed unsafe or defective?
Section 296-104-115. Inspection—What will be done when defective conditions are concealed by covering?
Section 296-104-125. Inspection—What are the requirements for obtaining a certificate of inspection?
Section 296-104-130. Inspection—When are inspection certificates valid?
Section 296-104-135. Inspection—What are the requirements for restamping of boilers and unfired pressure vessels?
Section 296-104-140. Inspection—How should a state number be assigned and applied?
Section 296-104-145. Inspection—How are groups of vessels operating as a single unit classified?
Section 296-104-150. Inspection—How are unfired steam boilers classified?
Section 296-104-151. Inspection—What are the requirements for rental boilers?
Section 296-104-155. Inspection—What preparations are necessary prior to internal inspections?
Section 296-104-160. Inspection—What happens if a boiler or unfired pressure vessel is improperly prepared for inspection?
Section 296-104-165. Inspection—When should coverings be removed for inspection?
Section 296-104-170. Inspection—When are shop inspections required?
Section 296-104-180. Inspection—How are radioactive systems inspected?
Section 296-104-200. Construction—What are the standards for new construction?
Section 296-104-205. Construction—What are the requirements for nonstandard new construction?
Section 296-104-210. Construction—What are the requirements for construction of boilers and unfired pressure vessels of special design?
Section 296-104-215. Construction—What are the requirements to use nonstandard boilers and unfired pressure vessels other than historical boilers and pressure vessels?
Section 296-104-220. Construction—What are the requirements to use nonstandard second hand boilers and unfired pressure vessels, other than historical boilers and pressure vessels?
Section 296-104-226. Construction—What are the requirements to use historical boilers and pressure vessels?
Section 296-104-245. Construction—Combustible fluid heaters.
Section 296-104-255. Installation—What are the required clearances for boilers?
Section 296-104-260. Installation—What are the required clearances for unfired pressure vessels?
Section 296-104-265. Installation—What are the requirements for unfired pressure vessels installed underground?
Section 296-104-271. Installation—How does an owner, user, or installer obtain a variance from clearances?
Section 296-104-273. Installation—What inspections are required for reinstalled standard boilers or unfired pressure vessels?
Section 296-104-295. Installation—What are the requirements for an explosion door?
Section 296-104-300. Installation—What control and limit devices are required on automatically fired boilers prior to June 1989?
Section 296-104-301. Installation—What control and limit devices are required on automatically fired boilers after June 1989?
Section 296-104-302. Installation—What fuel controls are required on automatically fired boilers after December 1998?
Section 296-104-303. Installation—What control and limit devices are required on automatically fired boilers after December 2004?
Section 296-104-307. Installation—When are platforms around boilers required?
Section 296-104-316. Installation—What safety pressure relief devices are required on boilers and unfired pressure vessels?
Section 296-104-320. Installation—Where should the discharge from safety pressure relief devices, blow offs and drains be directed?
Section 296-104-325. Installation—What are the requirements for boiler and unfired pressure vessel supports?
Section 296-104-405. Existing installation—How can the maximum allowable working pressure be established for nonstandard boilers or unfired pressure vessels?
Section 296-104-502. Repairs—What is the standard for nonnuclear repairs and alterations?
Section 296-104-503. Repairs—What are the requirements for nonnuclear boilers and unfired pressure vessel repairs and alterations?
Section 296-104-510. Repairs—When a lap seam crack is discovered along a riveted longitudinal joint on a boiler or unfired pressure vessel, what action is required and what repairs are allowed?
Section 296-104-515. Repairs—Do riveted repairs to boilers and unfired pressure vessels require prior approval?
Section 296-104-520. Repairs—What are the requirements for repair of nonnuclear safety devices?
Section 296-104-535. Repairs—What are the requirements for nuclear repairs/replacement?
Section 296-104-540. Repairs—What are the requirements for nuclear repairs of safety devices?
Section 296-104-700. What are the inspection fees—Examination fees—Certificate fees—Expenses?
Section 296-104-701. What are the civil penalties?