Washington Administrative Code (Last Updated: November 23, 2016) |
Title 296. Labor and Industries, Department of |
Chapter 296-96. Safety regulations and fees for all elevators, dumbwaiters, escalators and other conveyances. |
Section 296-96-23287. What requirements apply to suspension rope equalizers?
Latest version.
- Suspension rope equalizers, where provided, must be of the individual-compression spring type.Equalizers of other types may be used with traction elevators provided the equalizers and fastenings are approved by the authority having jurisdiction on the basis of adequate tensile and fatigue tests made by a qualified laboratory. Such tests must show the ultimate strength of the equalizer and its fastenings in its several parts and assembly, which must be no less than 10 percent in excess of the strength of suspension ropes, provided that equalizers of the single-bar type, or springs in tension, must not be used to attach suspension ropes to cars or counterweights or to dead-end hitch plates.EXCEPTION:The requirements of this section do not apply to rope equalizers that meet Rule 2.20.5 in ASME A17.1-2000.[Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-23287, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23287, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-23287, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23287, filed 12/22/00, effective 1/22/01.