Washington Administrative Code (Last Updated: November 23, 2016) |
Title 296. Labor and Industries, Department of |
Chapter 296-96. Safety regulations and fees for all elevators, dumbwaiters, escalators and other conveyances. |
Chapter 296-96. Safety regulations and fees for all elevators, dumbwaiters, escalators and other conveyances.
Section 296-96-00500. Scope, purpose, and authority. |
Section 296-96-00600. What rules apply to your conveyance? |
Section 296-96-00650. Which National Elevator Codes and Supplements has the department adopted? |
Section 296-96-00700. Chapter definitions. |
Section 296-96-00800. Advisory committee on conveyances. |
Section 296-96-00805. Appeal rights and hearings. |
Section 296-96-00900. In general, who is required to be licensed under this chapter? |
Section 296-96-00902. Are there exceptions from the elevator mechanic licensing requirements? |
Section 296-96-00903. Are there exceptions from the elevator contractor licensing requirements? |
Section 296-96-00904. What must you do to become and remain a licensed elevator contractor? |
Section 296-96-00906. What must you do to become a licensed elevator mechanic? |
Section 296-96-00907. ASME A17.1-8.11.1.5 Making safety devices ineffective. |
Section 296-96-00910. What are the elevator mechanic license categories? |
Section 296-96-00912. How long is the elevator contractor, elevator mechanic, and temporary mechanics licensing period and what is required for renewal? |
Section 296-96-00914. Where can you obtain information regarding department-approved continuing education course providers? |
Section 296-96-00916. Who approves and what is the process for becoming a continuing education course provider? |
Section 296-96-00918. Who is exempt from the continuing education requirements? |
Section 296-96-00920. When and where are elevator licensing examinations held? |
Section 296-96-00922. What are the fees associated with licensing? |
Section 296-96-00924. What procedures does the department follow when issuing a civil penalty for licensing violations? |
Section 296-96-00926. What are the civil (monetary) penalties for violating the licensing requirements of chapter 70.87 RCW or this chapter? |
Section 296-96-00930. What if I owe outstanding final judgments to the department? |
Section 296-96-01000. What is the permit process for conveyances? |
Section 296-96-01005. When do I need and what are the steps in obtaining a permit? |
Section 296-96-01006. What type of conveyance work requires permitting and inspection? |
Section 296-96-01008. Decommissioning a conveyance. |
Section 296-96-01009. Who can purchase a permit? |
Section 296-96-01010. What are the installation permit fees for conveyances, material lifts, and hoists and how are they calculated? |
Section 296-96-01012. What are the permit fees for alterations to conveyances, material lifts, and hoists and how are they calculated? |
Section 296-96-01025. What is the permit fee for personnel and material hoists? |
Section 296-96-01027. Are initial installation permit fees refundable? |
Section 296-96-01030. What is the process for installation and alteration plan approval? |
Section 296-96-01035. Are there inspection fees? |
Section 296-96-01040. What is the fee for testing and inspecting regular elevators used as temporary elevators to provide transportation for construction personnel, tools, and materials only? |
Section 296-96-01045. What are the inspection requirements and fees for conveyances in private residences? |
Section 296-96-01050. How do I get a supplemental inspection? |
Section 296-96-01055. Are technical services available and what is the fee? |
Section 296-96-01057. Does the department charge a fee to perform investigations and what is the fee? |
Section 296-96-01060. Can I request an after-hours inspection and what is the fee? |
Section 296-96-01065. What are the annual operating certificate fees? |
Section 296-96-01070. What are the civil (monetary) penalties for violating the conveyance permit and operation requirements of chapter 70.87 RCW and this chapter? |
Section 296-96-01075. How does an owner or licensee receive a variance from the installation and alteration requirements of chapter 70.87 RCW and this chapter? |
Section 296-96-02400. When must the department be notified for a new or altered inspection? |
Section 296-96-02401. ASME A17.1-8.7.1 Alteration general requirements. |
Section 296-96-02405. What is the inspection and approval process for alterations? |
Section 296-96-02410. Are there additional work requirements when performing an alteration? |
Section 296-96-02411. ASME A17.1-8.7.2.13 Door reopening devices. |
Section 296-96-02415. What are the conditions for obtaining a temporary construction operating permit? |
Section 296-96-02420. What are the requirements for temporary construction operating permits? |
Section 296-96-02421. Layout drawings. |
Section 296-96-02425. Where is a shut-off valve required for hydraulic elevators? |
Section 296-96-02450. Can pipes and ducts be installed above a machine room? |
Section 296-96-02451. When a control space is used in lieu of a machine room. |
Section 296-96-02452. Machines, beams and hitch supports must meet the following requirements. |
Section 296-96-02455. What is the minimum working space required in machine rooms/control rooms? |
Section 296-96-02460. What are the requirements for electrical main line disconnects? |
Section 296-96-02465. What are the requirements associated with elevator machine rooms? |
Section 296-96-02466. ASME A17.1-8.9 Code data plate location and material. |
Section 296-96-02470. What are the requirements for Fireman's Service Phase I and Phase II recall? |
Section 296-96-02471. ASME A17.1-2.27.8 FEO-K1 Fire service keys. |
Section 296-96-02475. What are the requirements for sprinklers in hoistways and machine rooms? |
Section 296-96-02480. How does the department enforce ASME requirements for sprinklers, smoke detectors, and heat detectors in hoistways and machine rooms? |
Section 296-96-02481. Sprinklers and shunt trip within the city limits of Seattle. |
Section 296-96-02485. What is required for emergency escape hatches? |
Section 296-96-02486. ASME A17.1-5.7.10.5 Special purpose elevator car doors or gates. |
Section 296-96-02490. Are there exceptions for correction facility elevators? |
Section 296-96-02495. Are self-leveling devices required? |
Section 296-96-02500. Is a door reopening device required on automatic-closing car doors? |
Section 296-96-02505. What is the minimum acceptable initial transfer time for an elevator door? |
Section 296-96-02510. What are the minimum cab size and other applicable requirements for car interiors? |
Section 296-96-02515. What is required for car controls? |
Section 296-96-02520. What are the location and operation requirements for car position indicators in the car? |
Section 296-96-02525. What is required for installation and operation of emergency communication systems? |
Section 296-96-02530. What requirements apply to the size and location of car handrails? |
Section 296-96-02535. What requirements apply to floor designations on elevator door jambs? |
Section 296-96-02540. What are the installation and operation requirements for hall buttons? |
Section 296-96-02545. What are the requirements for installation and operation of hall lanterns? |
Section 296-96-02550. ASME A17.1-3.18.3.8.3 and ASME A17.1-8.7.3.23.1—What are the requirements for underground hydraulic elevator pipes, fittings, and cylinders? |
Section 296-96-02551. ASME A17.1-2.6 and ASME A17.1-8.7.2.6 Protection of spaces below hoistways. |
Section 296-96-02552. Location of equipment in hoistway. |
Section 296-96-02555. What are the requirements for accessing elevated elevator pit equipment? |
Section 296-96-02556. Minimum width, clearances, and access of pit ladders. |
Section 296-96-02557. Pit lighting and stop switch. |
Section 296-96-02558. Pit equipment. |
Section 296-96-02560. What are the requirements for submersible pumps or sumps? |
Section 296-96-02564. ASME A17.1-2.4.12.1-2005 Distance required for car top refuge space. |
Section 296-96-02566. ASME A17.1-2.14.7.1.4 Requirements for top of car lighting and receptacle for elevators. |
Section 296-96-02567. ASME A17.1-2.7.6.3.4 Access to governors and brake. |
Section 296-96-02568. ASME A17.1-5.3.1.1 Residential hoistway enclosures. |
Section 296-96-02570. How do we enforce hoistway ventilation? |
Section 296-96-02575. How do we enforce hoistway pressurization? |
Section 296-96-02580. Are keys required to be on-site? |
Section 296-96-02585. What are the requirements for fire doors installed in front of hoistway doors? |
Section 296-96-02590. When does the department require a local building official to sign off for the installation of LULAs, stair lifts, inclined wheelchair lifts and vertical wheelchair lifts? |
Section 296-96-02595. What are the general requirements for LULA elevators? |
Section 296-96-02600. What is required for physically handicapped lifts? |
Section 296-96-02605. Private residence inclined stairway chairlifts. |
Section 296-96-02620. Private residence vertical platform lifts. |
Section 296-96-02625. Private residence incline platform lifts. |
Section 296-96-02630. Commercial vertical and incline platform lifts. |
Section 296-96-02640. Incline commercial stairway chair lifts. |
Section 296-96-05009. What are the requirements for existing material lifts? |
Section 296-96-05010. What are the department's rules on material lifts? |
Section 296-96-05020. What requirements apply to the construction and fire safety of hoistway enclosures? |
Section 296-96-05030. What are the construction requirements for hoistway enclosure gates and doors? |
Section 296-96-05040. What requirements apply to a hoistway that does not extend to the lowest levels of a building or structure? |
Section 296-96-05050. What requirements apply to lift hoist driving machines? |
Section 296-96-05070. What car enclosure requirements apply to lifts? |
Section 296-96-05080. How much running clearance is permitted between a car sill and a hoistway? |
Section 296-96-05090. What requirements apply to car and counterweight guides? |
Section 296-96-05100. How much weight can be placed on a car frame and platform during loading and unloading? |
Section 296-96-05120. What requirements apply to car operating devices, terminal stopping devices and electrical protective devices? |
Section 296-96-05140. What requirements apply to car safeties? |
Section 296-96-05150. What requirements apply to lift brakes? |
Section 296-96-05160. What types of ropes, chains, and rope connections must be used on a lift? |
Section 296-96-05170. What requirements apply to lift control stations? |
Section 296-96-05190. How must lift pits be constructed? |
Section 296-96-05200. Which lift landings must be illuminated? |
Section 296-96-05210. What signs must be posted on landings and lifts? |
Section 296-96-05220. What electrical wiring standards apply to lifts? |
Section 296-96-05230. What safety regulations apply to exposed equipment? |
Section 296-96-05240. What are the minimum maintenance requirements for lifts? |
Section 296-96-05260. When are inspections required? |
Section 296-96-05290. Under what conditions is a five-year test administered? |
Section 296-96-07010. What is the scope of Part C-2? |
Section 296-96-07020. What is the definition for inclined private residence elevator? |
Section 296-96-07021. What are the requirements for existing inclined private residence elevators? |
Section 296-96-07024. What rules apply to alterations of inclined private residence elevators? |
Section 296-96-07030. Does the department approve private residence elevator plans and specifications? |
Section 296-96-07035. What are the minimum maintenance requirements for inclined private residence elevators? |
Section 296-96-07040. What are the clearance requirements for an incline runway? |
Section 296-96-07050. What are the construction requirements for car landing enclosures and gates for inclined private residence elevators? |
Section 296-96-07060. What types of bumpers and buffers must be installed on inclined private residence elevators? |
Section 296-96-07070. What are the requirements for machinery beams and supports? |
Section 296-96-07080. What are the load and size requirements for car platforms? |
Section 296-96-07090. What is the maximum rated speed of an incline elevator? |
Section 296-96-07100. What construction requirements apply to inclined private residence elevators? |
Section 296-96-07110. What construction requirements apply to car enclosures? |
Section 296-96-07120. What construction requirements apply to car doors and gates? |
Section 296-96-07130. What type of glass or plastic can be used in a car enclosure? |
Section 296-96-07140. Are capacity and data plates required? |
Section 296-96-07150. What are the construction requirements for guide rails, track supports and fastenings? |
Section 296-96-07160. What construction requirements apply to counterweights? |
Section 296-96-07170. What are the requirements of safeties and governors? |
Section 296-96-07171. How and when are safeties and governors tested? |
Section 296-96-07180. What are the construction requirements for driving machines and sheaves? |
Section 296-96-07190. What construction requirements apply to terminal stopping switches? |
Section 296-96-07200. What are the requirements for operation of an inclined private residence elevator? |
Section 296-96-07210. What are the construction requirements for suspension methods? |
Section 296-96-07215. What are the requirements for controllers? |
Section 296-96-07220. What are the requirements for traveling cables? |
Section 296-96-07230. What requirements apply to electrical wiring? |
Section 296-96-07240. What are the requirements for track supporting structures? |
Section 296-96-07250. What additional requirements apply to inclined private residence elevators? |
Section 296-96-08010. What is the scope of Part C-3? |
Section 296-96-08020. What is the definition for inclined private residence conveyances for transporting property? |
Section 296-96-08022. What are the requirements for existing inclined private residence conveyances for transporting property? |
Section 296-96-08024. What rules apply to alterations of inclined private residence conveyances for transporting property? |
Section 296-96-08030. Does the department approve elevators plans and specifications for inclined private residence conveyances for transporting property? |
Section 296-96-08035. What are the minimum maintenance requirements for inclined private residence elevators for transporting property? |
Section 296-96-08050. What are the construction requirements for inclined private residence conveyances for transporting property for cars, landing gates, and enclosures? |
Section 296-96-08060. What types of bumpers and buffers must be installed on inclined private residence conveyances for transporting property? |
Section 296-96-08070. What are the requirements for machinery beams and supports? |
Section 296-96-08080. What are the load and size requirements for car platforms? |
Section 296-96-08090. What is the maximum rated speed of an inclined conveyance? |
Section 296-96-08100. What requirements apply to inclined conveyance? |
Section 296-96-08110. What requirements apply to car enclosures? |
Section 296-96-08140. Are capacity and data plates required on inclined private residence conveyances for transporting property? |
Section 296-96-08150. What are the requirements for guide rails, track supports and fastenings? |
Section 296-96-08160. What requirements apply to counterweights? |
Section 296-96-08170. What are the requirements of safeties and governors? |
Section 296-96-08175. How and when are conveyance safeties tested? |
Section 296-96-08180. What are the requirements for driving machines and sheaves? |
Section 296-96-08190. What requirements apply to terminal stopping switches? |
Section 296-96-08200. What are the requirements for the activation and operation of an inclined private residence conveyances for transporting property? |
Section 296-96-08210. What are the requirements for suspension methods? |
Section 296-96-08215. What are the requirements for controllers? |
Section 296-96-08220. What are the requirements for traveling cables? |
Section 296-96-08230. What requirements apply to electrical wiring? |
Section 296-96-08240. What are the requirements for track supporting structures? |
Section 296-96-08250. What additional requirements apply to inclined private residence conveyances for transporting property? |
Section 296-96-09001. What regulations apply to personnel hoists? |
Section 296-96-09002. May a drop plate be used for temporary hoists? |
Section 296-96-09003. What are the requirements for landing gates? |
Section 296-96-09004. Do jumps (increased travel) have to be inspected? |
Section 296-96-10001. What regulations apply to material hoists? |
Section 296-96-10002. Do jumps (increased travel) have to be inspected? |
Section 296-96-11001. What regulations apply to belt manlifts? |
Section 296-96-11010. What are the definitions for belt manlifts? |
Section 296-96-11016. What general requirements apply to belt manlift landings? |
Section 296-96-11019. What requirements apply to the guards and cones of belt manlift landings? |
Section 296-96-11022. What requirements apply to guarding lift entrances and exits? |
Section 296-96-11025. What structural requirements apply to floor opening guards? |
Section 296-96-11028. What structural requirements apply to floor landing guards? |
Section 296-96-11031. What requirements apply to bottom landings? |
Section 296-96-11034. What requirements apply to top clearance? |
Section 296-96-11037. What requirements apply to emergency exit ladders? |
Section 296-96-11040. What lighting requirements apply to belt manlifts? |
Section 296-96-11045. What drive machine requirements apply to belt manlifts? |
Section 296-96-11048. What is an acceptable operating speed for a belt manlift? |
Section 296-96-11051. What are the construction requirements for steps? |
Section 296-96-11054. What requirements apply to the location and construction of handholds? |
Section 296-96-11057. What requirements apply to "up-limit stops"? |
Section 296-96-11060. What requirements apply to emergency stops? |
Section 296-96-11066. What are the warning sign requirements? |
Section 296-96-11070. Can you carry tools and materials on a belt manlift? |
Section 296-96-11078. What is required for belt manlift inspections? |
Section 296-96-11080. Under what conditions is a five-year test administered? |
Section 296-96-13135. What are the requirements for electric manlifts? |
Section 296-96-13136. What are the minimum maintenance requirements for electric manlifts? |
Section 296-96-13139. What structural requirements apply to hoistway enclosures and landings? |
Section 296-96-13143. What structural requirements apply to hoistway gates and doors? |
Section 296-96-13145. What structural requirements apply to elevator cars? |
Section 296-96-13147. What structural requirements apply to elevator doors? |
Section 296-96-13149. What are the structural requirements for counterweights, counterweight enclosures, and counterweight fastenings? |
Section 296-96-13151. What construction requirements apply to car guide rails? |
Section 296-96-13153. What construction requirements apply to hoisting ropes? |
Section 296-96-13155. What are the requirements for a hoistway space? |
Section 296-96-13157. What requirements apply to car safeties? |
Section 296-96-13159. What requirements apply to brakes? |
Section 296-96-13161. What requirements apply to car controls and safety devices? |
Section 296-96-13167. What requirements apply to elevator driving machines? |
Section 296-96-13169. What requirements apply to car and counterweight buffers? |
Section 296-96-13171. What other requirements apply to electric manlifts? |
Section 296-96-14010. What is the scope and application of the department's hand-powered manlift rules? |
Section 296-96-14011. What are the minimum maintenance requirements for hand powered manlifts? |
Section 296-96-14020. What construction requirements apply to hoistway landings and entrances? |
Section 296-96-14025. What are acceptable hoistway clearances? |
Section 296-96-14030. Can there be a habitable space beneath an elevator hoistway or counterweight shaft? |
Section 296-96-14035. What construction requirements apply to hoistway guide rails? |
Section 296-96-14040. What installation requirements apply to buffer springs? |
Section 296-96-14045. What construction specifications apply to hoistway cars? |
Section 296-96-14050. What are the requirements for assembly, installation, and operation of sectional counterweights? |
Section 296-96-14055. What is the minimum acceptable sheave diameter? |
Section 296-96-14060. What requirements apply to hoisting ropes? |
Section 296-96-14065. What requirements apply to operating ropes? |
Section 296-96-14070. Where must hoistway lights be located? |
Section 296-96-14075. What is the factor of safety for overhead supports? |
Section 296-96-14080. What additional requirements apply to the installation and operation of hand powered manlifts? |
Section 296-96-16010. What is the scope of the department's casket lift regulations? |
Section 296-96-16011. What are the minimum maintenance requirements for casket lifts? |
Section 296-96-16020. What requirements apply to the location and operation of machine rooms and machinery space? |
Section 296-96-16030. What equipment can be located in a machine room? |
Section 296-96-16040. What requirements apply to the location of electrical wiring, pipes and ducts in hoistways and machine rooms? |
Section 296-96-16050. Is a pit required in a casket lift hoistway? |
Section 296-96-16060. What requirements apply to the size and location of hoistway door openings? |
Section 296-96-16070. How must hoistway doors be hung? |
Section 296-96-16080. Where must hoistway doors be located? |
Section 296-96-16090. What requirements apply to hoistway doors locks? |
Section 296-96-16100. How should space beneath a hoistway be protected? |
Section 296-96-16110. What requirements apply to car doors and gates? |
Section 296-96-16120. What requirements apply to car enclosures? |
Section 296-96-16130. What requirements apply to the construction of car frames and platforms? |
Section 296-96-16140. How must car frames and platforms be connected? |
Section 296-96-16150. What is the load capacity of a casket lift car? |
Section 296-96-16160. What types of casket lift driving machines are allowed? |
Section 296-96-16170. What material and grooving is required for sheaves and drums? |
Section 296-96-16180. What types of brakes must be used on the driving machine? |
Section 296-96-16190. Where must terminal stopping devices be located? |
Section 296-96-16200. What are the specifications for casket lift ropes and rope connections? |
Section 296-96-16210. What specific requirements apply to hydraulic casket lifts? |
Section 296-96-16220. What requirements apply to valves, supply piping, and fittings? |
Section 296-96-16230. What type of stopping devices must be installed? |
Section 296-96-16240. What type of operating devices must be used? |
Section 296-96-18010. What are the definitions for boat launching elevators? |
Section 296-96-18011. What are the minimum maintenance requirements for boat launch elevators? |
Section 296-96-18020. Must boat launching elevator cars and platforms be enclosed? |
Section 296-96-18030. What electrical wiring requirements apply to boat launching elevators? |
Section 296-96-18040. What type of brakes must be used on boat launching elevators? |
Section 296-96-18050. What types of stop switches and protective devices are required on boat launching elevators? |
Section 296-96-18060. When must hoisting cables be reshackled or refastened? |
Section 296-96-18070. What requirements apply to hoistway gates and doors? |
Section 296-96-18080. Must boat launching elevator hoistways be enclosed? |
Section 296-96-20005. What national safety codes has the department adopted for mechanized parking garage equipment? |
Section 296-96-20010. What are the minimum maintenance requirements for mechanized parking garage equipment? |
Section 296-96-23100. Are keys required to be on-site? |
Section 296-96-23101. What are the conveyance number requirements? |
Section 296-96-23105. What is the scope of Subpart I? |
Section 296-96-23110. What structural requirements apply to hoistway enclosures? |
Section 296-96-23111. Are guards required for windows in hoistway enclosures? |
Section 296-96-23113. What are the requirements for pipes in hoistways that convey gases, vapors, or liquids? |
Section 296-96-23115. What safety requirements apply to inspecting and maintaining overhead sheaves? |
Section 296-96-23116. What requirements apply to car numbers? |
Section 296-96-23117. What requirements apply to top of car railings for traction elevators? |
Section 296-96-23118. What requirements apply to top of car railings for hydraulic elevators in unenclosed hoistways? |
Section 296-96-23119. What signage requirements apply to traction elevators with minimal overhead clearance? |
Section 296-96-23121. What are the requirements for machine room and machinery space access? |
Section 296-96-23122. What type of lighting must be installed in machine rooms and machinery space? |
Section 296-96-23123. What type of service outlets must be installed in elevator cars, hoistways and machinery spaces? |
Section 296-96-23124. What installation requirements apply to pipes conveying gases, vapors, or liquids in machine rooms and machinery spaces? |
Section 296-96-23125. Must elevator machines and control equipment be protected from the weather? |
Section 296-96-23126. What protective measures should be taken in hoistways, machine rooms and machinery spaces to insure safety? |
Section 296-96-23130. What requirements apply to pit access? |
Section 296-96-23131. What requirements apply to pit drains? |
Section 296-96-23132. What lighting requirements apply to pits? |
Section 296-96-23133. What requirements apply to counterweight pit guards? |
Section 296-96-23140. What requirements apply to any space below a hoistway that is not permanently protected from access? |
Section 296-96-23150. Are hoistway doors (gates) required? |
Section 296-96-23151. What requirements apply to hoistway door closing devices? |
Section 296-96-23152. What requirements apply to hoistway door vision panels? |
Section 296-96-23153. What requirements apply to door hangers for horizontal slide doors? |
Section 296-96-23154. Are astragals required? |
Section 296-96-23155. What requirements apply to pull straps? |
Section 296-96-23156. What requirements apply to landing sill clearances? |
Section 296-96-23157. What is the maximum allowable threshold clearance? |
Section 296-96-23158. What requirements apply to elevator floor numbers? |
Section 296-96-23160. What requirements apply to hoistway door (gate) locking devices? |
Section 296-96-23161. What requirements apply to elevator parking devices? |
Section 296-96-23162. What requirements apply to hoistway door unlocking devices? |
Section 296-96-23165. What requirements apply to reopening devices for power-operated car doors and gates? |
Section 296-96-23166. What requirements apply to photo electric or electric eye door reopening devices? |
Section 296-96-23200. What is the scope of Subpart II? |
Section 296-96-23203. What requirements apply to buffers and bumpers? |
Section 296-96-23205. What requirements apply to counterweights? |
Section 296-96-23206. What requirements apply to car platforms and frames? |
Section 296-96-23207. What requirements apply to platform guards (aprons)? |
Section 296-96-23208. What requirements apply to hinged platform sills? |
Section 296-96-23209. What requirements apply to floating (movable) platforms? |
Section 296-96-23215. What requirements apply to car enclosures? |
Section 296-96-23216. What requirements apply to the lining materials used on passenger car enclosures? |
Section 296-96-23220. What requirements apply to car doors and gates? |
Section 296-96-23221. What requirements apply to the location of car doors and gates? |
Section 296-96-23222. What control requirements apply to operating circuits? |
Section 296-96-23225. What requirements apply to car emergency exits? |
Section 296-96-23226. What requirements apply to car lighting? |
Section 296-96-23227. What requirements apply to car safeties? |
Section 296-96-23228. What is the maximum amount of governor rope movement allowed when operating a safety mechanism? |
Section 296-96-23229. What requirements apply to rail lubricants and lubrication plates? |
Section 296-96-23235. What requirements apply to speed governors? |
Section 296-96-23236. What requirements apply to speed governor overspeed and car safety mechanism switches? |
Section 296-96-23240. What is the minimum rated load for passenger elevators? |
Section 296-96-23241. What requirements apply to the use of partitions that reduce inside net platform area? |
Section 296-96-23243. What is the minimum rated load for freight elevators? |
Section 296-96-23244. What requirements apply to capacity plates? |
Section 296-96-23245. What requirements apply to signs on freight elevators? |
Section 296-96-23250. What general requirements apply to driving machines and sheaves? |
Section 296-96-23255. What requirements apply to winding drum machines? |
Section 296-96-23256. What requirements apply to indirect-drive machines? |
Section 296-96-23260. What requirements apply to driving machine brakes? |
Section 296-96-23261. What requirements apply to the application and release of driving machine brakes? |
Section 296-96-23262. What requirements apply to normal terminal stopping devices? |
Section 296-96-23264. What requirements apply to final terminal-stopping devices? |
Section 296-96-23266. What types of operating devices must not be used? |
Section 296-96-23268. What requirements apply to car-switch operation elevators? |
Section 296-96-23269. What requirements apply to passenger elevator emergency stop buttons? |
Section 296-96-23270. What requirements apply to car top operating devices? |
Section 296-96-23272. What electrical protective devices are required? |
Section 296-96-23274. What requirements apply to the power supply line disconnect? |
Section 296-96-23276. What requirements apply to phase reversal and failure protection methods? |
Section 296-96-23277. What requirements apply to grounding and overcurrent protections? |
Section 296-96-23278. What requirements apply to the absorption of regenerated power? |
Section 296-96-23279. What requirements apply to door by-pass systems? |
Section 296-96-23280. What requirements apply to all car emergency signaling devices in all buildings? |
Section 296-96-23282. What requirements apply to suspension systems? |
Section 296-96-23283. What requirements apply to rope data tags? |
Section 296-96-23284. What is the factor of safety for wire suspension ropes? |
Section 296-96-23285. What is the minimum number of suspension ropes allowed? |
Section 296-96-23287. What requirements apply to suspension rope equalizers? |
Section 296-96-23288. What requirements apply to securing suspension wire ropes to winding drums? |
Section 296-96-23289. What requirements apply to spare rope turns on winding drum machines? |
Section 296-96-23290. What requirements apply to suspension rope fastenings? |
Section 296-96-23291. What requirements apply to auxiliary rope fastening devices? |
Section 296-96-23300. What is the scope of Subpart III, Hydraulic Elevators? |
Section 296-96-23302. What requirements apply to hoistways, hoistway enclosures and related construction? |
Section 296-96-23303. What requirements apply to hydraulic elevators without safety bulkheads? |
Section 296-96-23304. What requirements apply to buffers and bumpers? |
Section 296-96-23307. What requirements apply to car frames and platforms? |
Section 296-96-23309. What requirements apply to car enclosures? |
Section 296-96-23311. What requirements apply to capacity and loading? |
Section 296-96-23313. What requirements apply to driving machine connections? |
Section 296-96-23316. What requirements apply to plunger stops? |
Section 296-96-23318. What requirements apply to pump relief valves? |
Section 296-96-23321. What requirements apply to check valves? |
Section 296-96-23322. What requirements apply to supply piping and fittings? |
Section 296-96-23323. What requirements apply to flexible hydraulic connections? |
Section 296-96-23324. What general requirements apply to tanks? |
Section 296-96-23325. What requirements apply to pressure tanks? |
Section 296-96-23326. What requirements apply to terminal stopping devices? |
Section 296-96-23328. What requirements apply to operating devices? |
Section 296-96-23330. What requirements apply to car top operating devices? |
Section 296-96-23332. What requirements apply to anti-creep leveling devices? |
Section 296-96-23334. What requirements apply to electrical protective devices? |
Section 296-96-23336. What requirements apply to power supply line disconnects? |
Section 296-96-23338. What requirements apply to devices that make hoistway door interlocks or electric contacts and car door (gate) electric contacts inoperative? |
Section 296-96-23340. What requirements apply to control and operating circuits? |
Section 296-96-23342. What requirements apply to emergency operation and signaling devices? |
Section 296-96-23344. What additional requirements apply to counterweighted hydraulic elevators? |
Section 296-96-23400. What is the scope of Subpart IV, Escalators? |
Section 296-96-23405. What requirements apply to balustrades? |
Section 296-96-23408. How much clearance is required between skirt panels and step treads? |
Section 296-96-23410. What requirements apply to guards at ceiling or soffit intersections? |
Section 296-96-23412. What requirements apply to anti-slide devices? |
Section 296-96-23414. What requirements apply to handrails? |
Section 296-96-23416. What requirements apply to handrail guards? |
Section 296-96-23418. What requirements apply to step riser slotting? |
Section 296-96-23420. What requirements apply to step tread slotting? |
Section 296-96-23422. What requirements apply to combplates? |
Section 296-96-23424. What general requirements apply to escalator brakes? |
Section 296-96-23427. What requirements apply to main drive shaft brakes? |
Section 296-96-23429. What requirements apply to starting switches? |
Section 296-96-23431. What requirements apply to emergency stop buttons? |
Section 296-96-23432. What requirements apply to speed governors? |
Section 296-96-23434. What requirements apply to broken step-chain devices? |
Section 296-96-23436. What requirements apply to brake applications? |
Section 296-96-23438. What requirements apply to broken drive-chain devices? |
Section 296-96-23440. What requirements apply to skirt obstruction devices? |
Section 296-96-23442. What requirements apply to rolling shutter devices? |
Section 296-96-23444. What requirements apply to reversal stop device? |
Section 296-96-23446. What requirements apply to tandem operations? |
Section 296-96-23448. What requirements apply to caution signs? |
Section 296-96-23450. What requirements apply to step tread lighting? |
Section 296-96-23455. What requirements apply to comb and step distinction? |
Section 296-96-23460. What requirements apply to safety zone? |
Section 296-96-23465. What requirements apply to landing access plates? |
Section 296-96-23500. What is the scope of Subpart V, Dumbwaiters and Hand-powered elevators? |
Section 296-96-23510. What requirements apply to electric and electro-hydraulic dumbwaiters? |
Section 296-96-23540. What requirements apply to hand-power elevators and dumbwaiters? |
Section 296-96-23600. What is the scope of Part VI, Alterations, Repairs and Maintenance? |
Section 296-96-23601. ASME A17.1-8.6.1.2.1 General maintenance requirements for conveyances regulated by ASME A17.1 Part 8. |
Section 296-96-23602. ASME A17.1-8.6.1.4 Maintenance records. |
Section 296-96-23603. ASME A17.1-8.6.1.6.3(a) Wiring diagrams. |
Section 296-96-23604. ASME A17.1-8.6.1.7 Periodic tests. |
Section 296-96-23605. ASME A17.1-8.6.4 Maintenance, examination and testing of elevators. |
Section 296-96-23606. ASME A17.1-8.11 Covers periodic inspections, examinations, and tests of existing ASME A17.1 installations. |
Section 296-96-23610. What requirements apply to routine examinations and periodic or category 01, 03, and 05 safety tests? |
Section 296-96-23620. What requirements apply to alterations, repairs and maintenance? |
Section 296-96-23621. ASME A17.1-8.7.1.7 Repairs and replacement. |
Section 296-96-23630. What requirements apply to elevator equipment displaced by seismic activity? |
Section 296-96-23700. What is the scope of Subpart VII, Lifts for Physically Handicapped? |
Section 296-96-23701. Periodic examinations and safety tests. |
Section 296-96-23710. What requirements apply to lifts for the physically handicapped? |
Section 296-96-23800. What is the scope of Subpart VIII, Sidewalk Elevators? |
Section 296-96-23810. What requirements apply to electrically operated sidewalk elevators? |