Section 296-96-23160. What requirements apply to hoistway door (gate) locking devices?  


Latest version.
  • (1) Passenger elevator hoistway doors or gates must be equipped with hoistway-unit system door interlocks.
    (2) Freight elevator hoistway doors or gates must be equipped with hoistway-unit system door interlocks or an approved type combination electric contact and mechanical lock.
    (3) Combination locks and electric contacts or interlocks must be located so not to be accessible from the landing side when the hoistway doors or gates are closed.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23160, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23160, filed 12/22/00, effective 1/22/01.