Section 296-96-14080. What additional requirements apply to the installation and operation of hand powered manlifts?  


Latest version.
  • (1) Only employees and other authorized personnel may ride in a lift car.
    (2) Escape ladders must be installed extending the full length of the hoistway and must be located in a position so that in an emergency a person can safely transfer from the car platform to the ladder. Transfer is considered safe when a person can maintain three points of contact while making the transfer. An "IMPAIRED CLEARANCE" sign must be posted at the bottom of a ladder when the face of the ladder is less than 30 inches from any structure.
    (3) An automatic safety device which will prevent the car from leaving the landing until manually released by the operator must be installed at the bottom landing.
    (4) A fire extinguisher in proper working condition must be available in the car.
    (5) A five-year full load test must be performed and a tag indicating the date and the company conducting the test must be permanently attached with a wire and a seal. Documentation of the test submitted to the department. Manlifts with wooden rails must have a no-load drop test performed on the equipment.
    Qualified people will conduct the test. A qualified person is either:
    (a) An elevator mechanic licensed in the appropriate category for the conveyance being tested;
    (b) The representative of a firm that manufactured the particular conveyance and who holds a current temporary mechanic's license in this state; or
    (c) The representative of a firm that manufactured the particular conveyance who is working under the direct supervision of an elevator mechanic licensed in the appropriate category for the conveyance being tested.
    (6) A no load annual safety test must be performed and a tag indicating the date and company conducting the test must be attached to the conveyance with a wire and seal. A safety tag must also be permanently affixed to the inside of the car.
    [Statutory Authority: Chapter 70.87 RCW. WSR 08-23-085, § 296-96-14080, filed 11/18/08, effective 12/19/08. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-14080, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-14080, filed 12/22/00, effective 1/22/01.]
Chapter 70.87 RCW. WSR 08-23-085, § 296-96-14080, filed 11/18/08, effective 12/19/08. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-14080, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-14080, filed 12/22/00, effective 1/22/01.