- (1) ASME A17.1-2.4.2 When oil buffers are used, the bottom runby shall be not less than one hundred fifty millimeters (six inches). Sections (a) and (b) from the ASME A17.1-2.4.2.1 code are not adopted.(2) ASME A17.1-2.2.8 When working platform inspection operation is provided, according to ASME A17.1-2.7.5.3.6 in hoistways containing a single elevator:(a) A pit access door is required; or(b) Additional elevator personnel shall be present outside the hoistway when the pit inspection operation is in effect.[Statutory Authority: Chapter 70.87 RCW. WSR 13-24-066, § 296-96-02558, filed 11/27/13, effective 1/1/14.]