Washington Administrative Code (Last Updated: November 23, 2016) |
Title 296. Labor and Industries, Department of |
Chapter 296-818. Abrasive blasting. |
Section 296-818-40015. Inspection and maintenance.
Latest version.
- You must:• Make sure the exhaust ventilation system is fully operational by checking the static pressure drop at the exhaust ducts leading from the equipment at both of the following times:– When installation is completed– Annually after installation.• Repair or clean exhaust systems when either of the following occur:– Dust leaks are found; or– The pressure drop gauge indicates a change exceeding 20 percent.• Use an abrasive separator to separate larger particles for reuse on installations where abrasive is recirculated.• Set up dust collecting equipment to do both of the following:– Empty and remove accumulated dust without contaminating work areas– Discharge the air used in blast cleaning equipment.Note:Dispose fine dust from dry collectors by doing one of the following:• Emptying and transporting the fine dust in enclosed containers• Using a sluice with a wetting process to contain the dust.