Washington Administrative Code (Last Updated: November 23, 2016) |
Title 246. Health, Department of |
Chapter 246-359. Temporary worker housing construction standard. |
Section 246-359-310. Roof sheathing for wood framed construction and concrete masonry units.
Latest version.
- Roof sheathing shall be structural wood panels (plywood, OSB) with a minimum five-eighths inch thickness, grade stamped for use and span. Secure roof sheathing panels to the roof framing with 8d common nails, spaced six inches on center at the edges and twelve inches on center at intermediate supports.[Statutory Authority: RCW 70.114A.081. WSR 99-03-065, § 246-359-310, filed 1/18/99, effective 2/18/99.]
RCW 70.114A.081. WSR 99-03-065, § 246-359-310, filed 1/18/99, effective 2/18/99.