Section 246-272C-0125. Required application information.
Latest version.
- (1) Prefabricated tanks: The application for prefabricated tank design and construction approval must include the information listed in Table 1.Table 1—Required Application Information(2) Cast-in-place tank: The application for cast-in-place tank design and construction plan approval must include the following information:(a) Design drawings and supporting calculations stamped by a design engineer;(b) All tank design load limits including maximum traffic loading and earth loading;(c) Specific excavation, compaction, bedding, tank construction, and backfill requirements;(d) A signed and dated statement from the design engineer submitted with the design documents certifying the tank meets all standards and requirements of WAC 246-272C-0200 through 246-272C-0250; and(e) A signed and dated statement from the proprietary product manufacturer identifying the proprietary product model number, and stating the tank drawings were reviewed and found acceptable for use with the specified proprietary product.[Statutory Authority: RCW 43.20.050 (2) and (3). WSR 09-23-119, § 246-272C-0125, filed 11/18/09, effective 12/19/09.]
RCW 43.20.050 (2) and (3). WSR 09-23-119, § 246-272C-0125, filed 11/18/09, effective 12/19/09.