Washington Administrative Code (Last Updated: November 23, 2016) |
Title 246. Health, Department of |
Chapter 246-145. Body art, body piercing, electrology and tattooing standards for sterilization procedures and infection control. |
Section 246-145-030. Sterile procedures in electrology.
Latest version.
- To ensure that clients are not exposed to disease through needles or other instruments, electrologists must:(1) Use single-use, presterilized disposable needles on one client and then dispose of the needle immediately in a puncture-resistant container;(2) Not use reusable needles;(3) Use single-use sharp items on only one client and dispose of the items immediately in a puncture-resistant container;(4) Only reuse cleaned and sterilized sharp items and instruments that are intended for multiple use;(5) Thoroughly clean and sterilize reusable sharp items and instruments between clients;(6) Accumulate reusable sharp items and instruments in a holding container by submersion in a solution of a protein-dissolving enzyme detergent and water;(7) Sterilize reusable items in a steam autoclave or dry-heat sterilizer, which is used, cleaned and maintained according to the manufacturer's instructions;(8) Resterilize a reusable sterile instrument before using it on a client, if it is contaminated by dropping, by touching an unsterile surface, by a torn package, by the package being punctured, damaged, wet or by some other means;(9) Immediately dispose of a single-use item in a puncture-resistant container, if it is contaminated by dropping, by touching an unsterile surface, by a torn package, by the package being punctured, damaged, wet or by some other means;(10) Immediately dispose of an instrument in a puncture-resistant container if the expiration date has passed; and(11) Monitor sterilizers to determine that all conditions of sterilization are met. This includes:(a) Assuring that sterilizers have a thermometer and timer to indicate whether adequate heat has been applied to packaged equipment;(b) Using or checking chemical indicators on each package to assure the items have been exposed to the sterilization process;(c) Sterilizers must be tested by biological spore tests according to the manufacturer's instructions. In the event of a positive biological spore test, the electrologist must take immediate action to ensure all conditions of sterilization are met; and(d) Documentation of monitoring must be maintained either in the form of a log reflecting dates and person(s) conducting the testing or copies of reports from an independent testing entity. The documentation must be maintained at least three years.[Statutory Authority: RCW 70.54.340. WSR 10-12-057, § 246-145-030, filed 5/27/10, effective 7/1/10; WSR 02-11-109, § 246-145-030, filed 5/20/02, effective 6/20/02.]
RCW 70.54.340. WSR 10-12-057, § 246-145-030, filed 5/27/10, effective 7/1/10; WSR 02-11-109, § 246-145-030, filed 5/20/02, effective 6/20/02.