- TABLE R303.1.3(5)SMALL BUSINESS COMPLIANCE TABLEDEFAULT U-FACTORS FOR VERTICAL FENESTRATION1Low-eA (emissivity) shall be 0.24 to 0.16.Low-eB (emissivity) shall be 0.15 to 0.08.Low-eC (emissivity) shall be 0.07 or less.2Aluminum Thermal Break = An aluminum thermal break framed window shall incorporate the following minimum design characteristics:a)The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft2/°F;b)The thermal break material must produce a gap in the frame material of not less than 0.210 inches; andc)All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in a and b above.3A minimum air space of 0.375 inches between panes of glass is required for double glazing.4A minimum air space of 0.25 inches between panes of glass is required for triple glazing.5Deemed to comply glazing shall not be used for performance compliance.[Statutory Authority: RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. WSR 13-04-055, § 51-11R-30315, filed 2/1/13, effective 7/1/13.]