- TABLE R303.1.3(1)DEFAULT GLAZED FENESTRATION U-FACTORaMetal Thermal Break = A metal thermal break framed window shall incorporate the following minimum design characteristics:1) The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft2/°F;2) The thermal break material must produce a gap in the frame material of not less than 0.210 inches; and3) All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in a) and b) above.[Statutory Authority: RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. WSR 13-04-055, § 51-11R-30311, filed 2/1/13, effective 7/1/13.]
RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. WSR 13-04-055, § 51-11R-30311, filed 2/1/13, effective 7/1/13.