Section 51-11C-61062. Section A106.2—Component description.
Latest version.
- A106.2 Component description. All on-grade slab floors are assumed to be 6 inch concrete poured directly onto the earth. The bottom of the slab is assumed to be at grade line. Monolithic and floating slabs are not differentiated.Soil is assumed to have a conductivity of 0.75 Btu/h • ft2 • °F. Slabs 2 feet or more below grade should use basement coefficients.[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-61062, filed 2/1/13, effective 7/1/13.]