- A106.1 General. Table A106.1 lists heat loss coefficients for heated on-grade slab floors, in units of Btu/h • °F per lineal foot of perimeter.Table A106.1Default F -factors for On-Grade SlabsInsulation TypeR-0R-5R-10R-15R-20R-30Unheated SlabUninsulated slab0.73—————2 ft. Horizontal (No thermal break)—0.700.700.69——4 ft. Horizontal (No thermal break)—0.670.640.63——2 ft. Vertical—0.580.540.52——4 ft. Vertical—0.540.480.45——Fully insulated slab*——0.360.310.260.21Heated SlabUninsulated slab0.84—————Fully insulated slab*—0.740.550.440.390.32R-5 Center (With perimeter insulation)——0.660.62——R-10 Center (With perimeter insulation)———0.51——3 ft. Vertical——0.78———*Edge insulation R-10 regardless of the below slab insulation level.[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-61061, filed 2/1/13, effective 7/1/13.]
RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-61061, filed 2/1/13, effective 7/1/13.