Washington Administrative Code (Last Updated: November 23, 2016) |
Title 51. Enterprise Services, Department of (Building Code Council) |
Chapter 51-11C. State Building Code adoption and amendment of the 2015 edition of the International Energy Conservation Code, Commercial. |
Section 51-11C-610226. Tables A102.2.6—Assembly U-factors for roofs with insulation entirely above deck.
Latest version.
- Table A102.2.6(1)Assembly U-factors for Roofs with Tapered Insulation Entirely Above Deck Single Slope Rectangular to One-sided,e,f,g,h(Uninterrupted by Framing)Table A102.2.6(2)Assembly U-factors for Roofs with Tapered Insulation Entirely Above Deck Sloped Triangle (Roof with Center Drain)e,f,g,h,i(Uninterrupted by Framing)Table A102.2.6(3)Assembly U-factors for Roofs with Tapered Insulation Entirely Above Deck Sloped Triangle (Roof with Perimeter Drains)e,f,g,h,i(Uninterrupted by Framing)Footnotes to Tables A102.2.6(1), A102.2.6(2), and A102.2.6(3):a Rmax and Rmin are determined along the linearly tapered cross section for the 6. respective minimum and maximum thickness values for the roof section being analyzed. For triangular roof sections.b Rmax refers to the insulation value along the long edge of the triangle and Rmin to the insulation at the point of the triangle which assumes that the insulation slopes to the center.c Rmax refers to the insulation value at the point of the triangle and Rmin to the insulation along the long edge of the triangle which assumes that the insulation slopes to the perimeter.d Effective U-factor for rectangular tapered insulation is calculated as follows:Reff=Rmax – RminLn[Rmax/Rmin]e Effective U-factor for triangular tapered insulation is calculated as follows:Reff = [2/(Rmax – Rmin) [1 + (Rmin/Rmax – Rmin)ln(Rmin/Rmax)]]-1f Assembly U-factors include an exterior air film (R=0.17) and an interior air film, horizontal with heat flow up (R=0.61).g For effective U-factors of roof assemblies with different Rmax or Rmin values not listed in the tables interpolation is allowed.h This table shall only be applied to tapered insulation that is tapered along only one axis.i In areas of differing insulation slopes/configurations, individual U-values shall be calculated and an area weighted U-value calculation shall be used to determine the effective value of the roof.[Statutory Authority: RCW 19.27A.025, 19.27A.160, and 19.27.074. WSR 16-03-072, § 51-11C-610226, filed 1/19/16, effective 7/1/16. Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-610226, filed 2/1/13, effective 7/1/13.]Reviser's note: The brackets and enclosed material in the text of the above section occurred in the copy filed by the agency.
RCW 19.27A.025, 19.27A.160, and 19.27.074. WSR 16-03-072, § 51-11C-610226, filed 1/19/16, effective 7/1/16. Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-610226, filed 2/1/13, effective 7/1/13.