Washington Administrative Code (Last Updated: November 23, 2016) |
Title 51. Enterprise Services, Department of (Building Code Council) |
Chapter 51-11C. State Building Code adoption and amendment of the 2015 edition of the International Energy Conservation Code, Commercial. |
Section 51-11C-303135. Table C303.1.3(5)—Small business compliance default table.
Latest version.
- Table C303.1.3(5)Small Business Compliance TableDefault U-Factors for Vertical Glazing1Low-eA (emissivity) shall be 0.24 to 0.16.Low-eB (emissivity) shall be 0.15 to 0.08.Low-eC (emissivity) shall be 0.07 or less.2Aluminum Thermal Break = An aluminum thermal break framed window shall incorporate the following minimum design characteristics:a)The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft2/°F;b)The thermal break material must produce a gap in the frame material of not less than 0.210 inches; andc)All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in a) and b) above.3A minimum air space of 0.375 inches between panes of glass is required for double glazing.4A minimum air space of 0.25 inches between panes of glass is required for triple glazing.5Deemed to comply glazing shall not be used for performance compliance.[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-303135, filed 2/1/13, effective 7/1/13.]
RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-303135, filed 2/1/13, effective 7/1/13.