Section 296-96-23540. What requirements apply to hand-power elevators and dumbwaiters?  


Latest version.
  • (1) Cars of hand-power elevators and dumbwaiters must be enclosed on all sides not used for entrance. Elevator cars upon which an operator is permitted to ride must have no more than one compartment.
    (2) Hand elevators having a travel of more than 15 feet must have a car safety, capable of stopping and sustaining the car and rated load. The car safety device need not be operated by a speed governor and may be of the instantaneous type operated as a result of the breaking and slackening of the suspension members.
    (3) Hoistway doors for hand-powered elevators must be designed so that they will ensure protection at each landing.
    (4) Doors for hand-powered dumbwaiters must be designed so that they will ensure protection at all landings.
    (5) Every hoistway door, gate, or entrance of hand elevators and hand dumbwaiters must have conspicuously displayed on the landing side in letters no less than 2 inches high, the words "Danger—Elevator—Keep closed," or "Danger—Dumbwaiter—Keep closed."
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23540, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23540, filed 12/22/00, effective 1/22/01.