Section 296-96-23278. What requirements apply to the absorption of regenerated power?  


Latest version.
  • When a power source is used which, in itself, is incapable of absorbing the energy generated by an overhauling load, means for absorbing sufficient energy to prevent the elevator from attaining governor tripping speed or a speed in excess of 125 percent of rated speed, whichever is lesser, must be provided on the load side of each elevator power supply line disconnecting means.