Section 296-96-23166. What requirements apply to photo electric or electric eye door reopening devices?
Latest version.
- An elevator equipped with a photo electric or electric eye device for reopening of the car and hoistway doors must be provided with a means that will automatically time-out and close the door if it has been obstructed for 20 seconds. The photo electric or electric eye device must not be reactivated until the doors have fully closed. There are two exceptions to this requirement:(1) The department may authorize hospitals or nursing homes to allow obstructed doors to close within 35 seconds after the expiration of the normal door open time.(2) When smoke detectors are used to bypass photo electric or electric eye devices the doors are not required to time-out and close except under phase I conditions as authorized by ANSI A17.1-211.3A.