Section 296-96-23153. What requirements apply to door hangers for horizontal slide doors?  


Latest version.
  • Door hangers for horizontal slide type entrances must meet the following requirements:
    (1) Means must be provided to prevent the hangers from jumping the track.
    (2) Stops must be provided in the entrance assembly to prevent hangers from overrunning the end of the track.
    (3) Power-operated doors must be built to withstand, without damage or appreciable deflection, an imposed static load equal to four times the weight of each panel. This static load must be applied successively downward and upward along the vertical centerline of the panel.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23153, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-23153, filed 12/22/00, effective 1/22/01.