Section 296-96-23150. Are hoistway doors (gates) required?  


Latest version.
  • (1) Passenger elevators. Hoistway landing openings must have entrances which guard the full width and height of the openings. The panels of entrances used with automatic-operation passenger elevators must not have hand latches or other hand operated door fastening devices, nor must such panels
    (2) Freight elevators. Hoistway landing openings for freight elevators must have entrances which guard the full width of the opening. Gates and doors must meet the following requirements:
    (a) Balanced type vertically sliding hoistway gates must extend from a point not more than 2 inches from the landing threshold to a point at least 66 inches above the threshold.
    (b) Gates must be solid or openwork of a design that will reject a 2 inch diameter ball and be located so that the distance from the hoistway face of the gate to the hoistway edge of the landing sill is no more than 2 1/2 inches.
    (c) Gates must be constructed of metal or wood and be designed and guided so as to withstand a lateral pressure of 100 pounds applied at approximately the center without breaking or becoming permanently deformed and without displacing the gate from its guides or tracks.
    (d) At the top landing, a gate 66 inches high may be used if there is not sufficient clearance for a 6 feet high gate. When the requirements of WAC 296-96-23110 allow nonfire-resistive hoistway enclosures, a gate may be used.
    (e) Gates must be constructed of either metal or wood.
    (f) Gates must withstand a lateral pressure of 100 pounds, applied at approximately their center, without breaking, being permanently deformed or being displaced from their guides or tracks.
    (g) The maximum vertical opening between a landing sill and a door or gate is 2 inches.
    (h) The distance between the gate's hoistway face and the hoistway landing edge must not exceed 2 1/2 inches.