Section 296-96-16200. What are the specifications for casket lift ropes and rope connections?  


Latest version.
  • (1) Elevator cars and counterweights must be suspended by steel wire ropes. Only iron (low carbon steel) or steel wire ropes with fibre cores, having the commercial classification of "elevator wire rope" may be used for the suspension of elevator cars and for the suspension of counterweights.
    (2) The minimum number of hoisting ropes is:
    (a) Three 1/2 inch ropes for traction elevators; and
    (b) Two 1/2 inch ropes for drum type elevators.
    (3) Fastenings must be by individual tapered babbitted rope sockets or by other department-approved types.
    (4) The rope sockets must be of a type which will develop at least 80 percent of the braking strength of the strongest rope to be used in such fastenings, and U-bolt type rope clips (clamps) must not be used for load line fastenings.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16200, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16200, filed 12/22/00, effective 1/22/01.