Section 296-96-16120. What requirements apply to car enclosures?  


Latest version.
  • (1) Elevator cars must be permanently enclosed on all sides and the top.
    (2) The enclosure must be securely fastened to the car platform and so supported that it cannot loosen or become displaced in ordinary service.
    (3) The enclosure walls must be of sufficient strength and designed and supported so that when subjected to a pressure of 75 pounds applied horizontally at any point on the walls of the enclosure, the deflection will not reduce the running clearance to exceed one inch.
    (4) The top of the car enclosure must be designed and installed so as to be capable of sustaining a load of 300 pounds on any square area 2 feet on a side and 100 pounds applied at any point. Simultaneous application of these loads is not required.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16120, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16120, filed 12/22/00, effective 1/22/01.