Section 296-96-16020. What requirements apply to the location and operation of machine rooms and machinery space?  


Latest version.
  • (1) Machines and control equipment can be located:
    (a) Inside a hoistway enclosure, at the top or bottom, without enclosures or platforms; or
    (b) Outside a hoistway if enclosed with a noncombustible material to a height of at least 6 feet.
    (2) Machines and control equipment located outside the hoistway must be enclosed in enclosures of incombustible material not less than 6 feet high and have a self-closing and locking door. Control equipment located outside the hoistway may be enclosed in metal cabinet equipped with a self-closing and locking door to prevent access by unauthorized persons.
    (3) Permanent electric lighting must be provided in all machine rooms and machinery spaces.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16020, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-16020, filed 12/22/00, effective 1/22/01.