Section 296-96-11016. What general requirements apply to belt manlift landings?  


Latest version.
  • (1) Vertical clearance between the floor or mounting platform and the lower edge of the conical guard above it must be at least 7 feet, 6 inches. When this clearance is not possible, access to the manlift must be prohibited and the space where the runway passes through the platform floor must be enclosed.
    (2) Floor space adjacent to floor openings must be kept clear and free of obstructions at all times.
    (3) Adequate lighting (not less than 5 foot-candle power) must be provided at each floor landing whenever the lift is in use.
    (4) The landing surfaces at all entrances and exits must provide safe footing and must have a coefficient of friction of at least 0.5 to help insure safe footing.
    (5) Emergency landings must be provided so that the maximum distance a person must travel on the emergency ladder between an emergency landing and a floor landing is 25 feet. Emergency landings must:
    (a) Be accessible from both runs of the lift;
    (b) Give access to the emergency ladder; and
    (c) Be completely enclosed with a standard railing and toeboard.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-11016, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-11016, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-11016, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-11016, filed 12/22/00, effective 1/22/01.