Latest version.
- (1) Inclined conveyance elevator frames and platforms must:(a) Be built of metal, a combination of metal and wood or other materials of equal strength;(b) Have a safety factor of at least 5; and(c) Be suitably prepared and/or protected from exposure to weather.(2) Inclined conveyance chassis must:(a) Be built of metal, except for the guiding members;(b) Have a safety factor of at least 5, based upon the conveyance's rated load; and(c) Have the chassis guiding members retained and/or enclosed in guides so that the chassis cannot be derailed.(3) Cast iron may not be used in the construction of the conveyance frame or chassis.(4) A car may have only one compartment.[Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-08100, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-08100, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-08100, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-08100, filed 12/22/00, effective 1/22/01.