Section 296-96-07250. What additional requirements apply to inclined private residence elevators?  


Latest version.
  • (1) All inclined private residence elevators must be equipped with:
    (a) A Manual method of moving the elevator in accordance with ASME A17.1; and
    (b) A machine brake with a lever to release the brake allowing use of the manual method.
    (2) Machinery spaces must be protected from weather and accidental contact. Machinery spaces must be locked.
    (3) Guiding members and moving parts of the inclined private residence elevator must be free of brush and other types of material that might either impede the travel or cause deterioration of the equipment over time.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-07250, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-07250, filed 12/22/00, effective 1/22/01.]
RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and 2004 c 66. WSR 04-12-047, § 296-96-07250, filed 5/28/04, effective 6/30/04. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-07250, filed 12/22/00, effective 1/22/01.