Section 296-96-07120. What construction requirements apply to car doors and gates?  


Latest version.
  • (1) All car entrances must be protected by a door or gate. The height of the door or gate must be at least 42 inches and equal to the height of the car enclosure. Doors and gates may be either of a solid design or an openwork design. If of an openwork design, the door or gate must be able to reject a 3-inch diameter ball. After the effective date of these rules the diameter will be reduced to 1.5 inches.
    (2) Car doors or gates must be equipped with an electric contact that prevents the elevator from operating unless the door or gate is securely closed. If the gate is a swing type opening outward from the car, the electric contact must not be made until the gate is securely latched.
    (3) All car doors or gates must be manually operated.
    [Statutory Authority: Chapter 70.87 RCW. WSR 07-24-041, § 296-96-07120, filed 11/30/07, effective 1/1/08. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-07120, filed 12/22/00, effective 1/22/01.]
Chapter 70.87 RCW. WSR 07-24-041, § 296-96-07120, filed 11/30/07, effective 1/1/08. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-07120, filed 12/22/00, effective 1/22/01.