Section 296-96-07040. What are the clearance requirements for an incline runway?  


Latest version.
  • (1) If the car sides extend less than 6 feet above the floor of the car, there must be no obstruction along the runway within 24 inches of the car sides. EXCEPTION: When solid guards are installed on the obstruction in both directions of travel which project at least 14 inches in line with the direction of travel, the running clearance may be reduced to 7 inches. The guard must be arched and the edges rounded to eliminate shear hazard.
    (2) Guiding members and moving parts of the inclined private residence elevator must be kept free of brush and other types of material that might either impede the travel or cause deterioration of the equipment over time.
    [Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-07040, filed 12/22/00, effective 1/22/01.]