  • (1) Motor controllers, motion controller, drive, hydraulic control valves, hydraulic reservoir (tank), and hydraulic pump motor shall not be located in the hoistway or pit.
    (2) Elevator controls and machinery other than driving machines, hydraulic cylinder, piston, governor, and their components shall be located in a room dedicated exclusively to elevator equipment.
    (3) Drive sheaves, deflector sheaves, machine parts and supports are permitted to project into the hoistway.
    (4) Driving machines shall not be located in the pit.
    [Statutory Authority: Chapter 70.87 RCW. WSR 13-24-066, § 296-96-02552, filed 11/27/13, effective 1/1/14.]