Section 296-96-02421. Layout drawings.  


Latest version.
  • Two sets of legible layout/plans must be submitted to the department, in addition to the layout criteria in ASME, include the following:
    (1) A machine room plan identifying room dimensions, location of drive machine and motor controller, mainline disconnect, outlet, light switch, and door swing;
    (2) A hoistway plan identifying hoistway and conveyance equipment dimensions and clearances, foot print of cab showing doors and inside cab dimensions, and location and dimensions of hoistway and cab door or gates;
    (3) A hoistway elevation section identifying elevation of the hoistway and conveyance equipment dimensions and clearances, location of rail brackets, pit ladder, pit light, light switch, pit stop switch, top of car clearances, and on MRLs the height to the equipment from the horizontal plane of the top of the car with the car positioned at the top landing; and
    (4) Detail drawings identifying specific details of conveyance components: Rail bracket fastening, sill support and fastening, machine beams, entrance installation assembly, loads and reactions, and additional seismic requirements (when required by building code).
    General conveyance data includes:
    (a) Conveyance type (model) and capacity;
    (b) Location number (within building);
    (c) Up/down full load speed;
    (d) Car enclosure (construction material);
    (e) Door type and manufacturer (single speed, two-speed, center opening, RH/LH opening);
    (f) Platform thickness;
    (g) Finish floor (tile, carpet);
    (h) Power unit/drive motor (manufacturer and HP);
    (i) Power requirements;
    (j) Equipment heat generation (BTU) (Items (k)-(o) are applicable to hydraulic);
    (k) Jack model;
    (l) Plunger O.D. (if telescoping O.D. of each section);
    (m) Plunger wall thickness;
    (n) Cylinder O.D.;
    (o) Cylinder wall thickness (items (p)-(u) are applicable to roped-hydraulic and electric);
    (p) Size and number of hoist ropes;
    (q) Roping type (1:1, 2:1, underslung);
    (r) Governor location;
    (s) Governor rope size and number;
    (t) Safety manufacture and type;
    (u) Emergency brake manufacture and type;
    (v) Care buffer type and stroke;
    (w) CWT buffer type, impact, and stroke; and
    (x) Top/bottom runby.
    [Statutory Authority: Chapter 70.87 RCW. WSR 13-24-066, § 296-96-02421, filed 11/27/13, effective 1/1/14.]
Chapter 70.87 RCW. WSR 13-24-066, § 296-96-02421, filed 11/27/13, effective 1/1/14.