Section 296-874-30046. Meet these requirements when using two-point adjustable suspension scaffolds (swing stages).  


Latest version.
  • Important:
    This section does not apply to two-point adjustable suspension scaffolds used as masons' or stonesetters' scaffolds.
    Reference:
    For requirements for masons' or stonesetters' scaffolds, go to WAC 296-874-30040.
    (1) You must make sure platforms more than thirty-six inches (0.9 m) wide have been designed by a qualified person to prevent unstable conditions.
    (2) You must make sure platforms are one of the following:
    (a) Ladder-type;
    (b) Plank-type;
    (c) Beam-type;
    (d) Light-metal type.
    (3) You must make sure the design of light-metal type platforms have been tested and listed by a nationally recognized testing laboratory if they:
    (a) Have a rated capacity of seven hundred fifty pounds or less; or
    (b) Have a length of forty feet (12.2 m) or less.
    (4) You must securely fasten the platform to the hangers (stirrups) using U-bolts or other means that satisfy the section titled, Make sure suspended scaffolds and scaffold components meet these strength requirements, WAC 296-874-30002.
    (5) You must make sure fiber or synthetic ropes are used with blocks that:
    (a) Consist of at least one double and one single block and;
    (b) Have sheaves that fit the size of the rope used.
    (6) You must make sure employees move from one platform to another only when all of the following are met:
    (a) The platforms are at the same height;
    (b) The platforms are abutting;
    (c) Walk-through stirrups are used that have been specifically designed to allow employee passage.
    (7) You must make sure two-point scaffolds that are bridged or otherwise connected together when being raised or lowered meet both of the following:
    (a) The bridge connections are articulated;
    (b) The hoists are properly sized.
    Reference:
    For specific fall protection requirements for employees on two-point adjustable suspension scaffolds, go to WAC 296-874-20056.
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-874-30046, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 05-01-054, § 296-874-30046, filed 12/7/04, effective 3/1/05.]
RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-874-30046, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 05-01-054, § 296-874-30046, filed 12/7/04, effective 3/1/05.