Section 296-870-60010. Stabilization systems.  


Latest version.
  • (1) You must make sure the exterior of each building is provided with at least one of the following stabilization systems:
    (a) Continuous tie-in guides;
    (b) Intermittent stabilization system;
    (c) Button guide stabilization system;
    (d) System using angulated roping and building face rollers;
    (e) System equivalent to a continuous tie-in guide system.
    EXEMPTION:
    • Tie-in guides may be eliminated for not more than seventy-five feet (22.9 m) of the uppermost elevation of the building if:
     
    1. Using tie-in guides there is not feasible due to building design;
     
    AND
     
    2. Angulated roping is used that provides a stabilizing force of at least ten pounds (44.4 n) under all conditions of loading.
    (2) You must make sure embedded tie-down anchors, fasteners, and affected structures are corrosion-resistant.