Section 296-863-30040. Service batteries for electric PITs safely.  


Latest version.
  • You must:
    • Make sure PITs are properly positioned with the brake on before charging or changing batteries.
    • Make sure you do not use open flames to check the electrolyte level in storage batteries.
    • Do the following when charging batteries:
    – Make sure vent caps are functioning.
    – Open the battery or compartment covers to dissipate heat.
    – Pour acid into water, never pour water into acid.
    • Provide a carboy tilter or siphon to handle electrolyte.
    • Keep tools and other metallic objects away from the top of uncovered batteries.
    • Make sure reinstalled batteries are properly positioned and secured.
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 04-19-051, § 296-863-30040, filed 9/14/04, effective 2/1/05.]
RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 04-19-051, § 296-863-30040, filed 9/14/04, effective 2/1/05.