Section 296-835-140. Definitions.


Latest version.
  • ACGIH: American Conference of Governmental Industrial Hygienists.
    Adjacent area: Any area within twenty feet (6.1 m) of a vapor area that is not separated from the vapor area by tight partitions.
    ANSI: American National Standards Institute.
    Approved: Approved or listed by a nationally recognized testing laboratory. Refer to federal regulation 29 C.F.R. 1910.7, for definition of nationally recognized testing laboratory.
    Autoignition temperature: The minimum temperature required to cause self-sustained combustion without any other source of heat.
    Detearing: A process for removing excess wet coating material from the bottom edge of a dipped or coated object or material by passing it through an electrostatic field.
    Dip tank: A container holding a liquid other than plain water that is used for dipping or coating. An object may be immersed (or partially immersed) in a dip tank or it may be suspended in a vapor coming from the tank.
    Flammable liquid: Any liquid having a flashpoint at or below 199.4°F (93°C). Flammable liquids are divided into four categories as follows:
    (a) Category 1 shall include liquids having flashpoints below 73.4°F (23°C) and having a boiling point at or below 95°F (35°C).
    (b) Category 2 shall include liquids having flashpoints below 73.4°F (23°C) and having a boiling point above 95°F (35°C).
    (c) Category 3 shall include liquids having flashpoints at or above 73.4°F (23°C) and at or below 140°F (60°C). When a Category 3 liquid with a flashpoint at or above 100°F (37.8°C) is heated for use to within 30°F (16.7°C) of its flashpoint, it shall be handled in accordance with the requirements for a Category 3 liquid with a flashpoint below 100°F (37.8°C).
    (d) Category 4 shall include liquids having flashpoints above 140°F (60°C) and at or below 199.4°F (93°C). When a Category 4 flammable liquid is heated for use to within 30°F (16.7°C) of its flashpoint, it shall be handled in accordance with the requirements for a Category 3 liquid with a flashpoint at or above 100°F (37.8°C).
    (e) When liquid with a flashpoint greater than 199.4°F (93°C) is heated for use to within 30°F (16.7°C) of its flashpoint, it shall be handled in accordance with the requirements for a Category 4 flammable liquid.
    Flashpoint: Means the minimum temperature at which a liquid gives off a vapor within a test vessel in sufficient concentration to form an ignitable mixture with air near the surface of the liquid, and shall be determined as follows:
    (a) The flashpoint of liquids having a viscosity less than 45 Saybolt universal second(s) at 100°F (37.8°C) and a flashpoint below 175°F (79.4°C) shall be determined in accordance with the Standard Method of Test for Flashpoint by the Tag Closed Tester, ASTM D-56-69 (incorporated by reference; WAC 296-901-14024, Appendix B—Physical hazard criteria).
    (b) The flashpoints of liquids having a viscosity of 45 Saybolt universal second(s) or more at 175°F (79.4°C) or higher shall be determined in accordance with the Standard Method of Test for Flashpoint by the Pensky Martens Closed Tester, ASTM D-93-69 (incorporated by reference; WAC 296-901-14024, Appendix B—Physical hazard criteria).
    Lower flammable limit: The lowest concentration of a material that will propagate a flame. The LFL is usually expressed as a percent by volume of the material in air (or other oxidant).
    NFPA: National Fire Protection Association.
    Vapor area: Any area in the vicinity of dip tanks, their drain boards or associated drying, conveying, or other equipment where the vapor concentration could exceed twenty-five percent of the lower flammable limit (LFL) for the liquid in the tank.
    You: Means the employer. See the definition of employer in the safety and health core rules, WAC 296-800-370.