Section 296-809-60002. Make sure the following conditions are met if using alternate entry procedures.
Latest version.
- (1) You must make sure, when using alternate entry procedures, instead of permit entry procedures, that you have monitoring and inspection data that supports the following:(a) That the only hazard of the permit-required confined space is an actual or potentially hazardous atmosphere.(b) That continuous forced air ventilation alone is all that is needed to maintain the permit-required confined space for safe entry.(2) You must make sure an entry to obtain monitoring and inspection data or to eliminate hazards is performed according to WAC 296-809-500, Permit entry procedures.(3) You must make sure all documentation produced is available to each affected employee and their authorized representative.
Rules
296-809-500,