Section 296-803-50005. Use energy control procedures.  


Latest version.
  • You must:
    • Use energy control procedures to protect employees servicing or maintaining machines and equipment from potentially hazardous energy.
    • Use a lockout system if an energy-isolating device can be locked out.
    Exemption:
    A tagout system may be used instead of a lockout system if it meets all of the following:
     
    • The tagout device is attached where you would have put the lockout device.
     
    • The tagout system provides the same level of employee protection as a lockout system.
     
    • You can demonstrate that the tagout system:
     
    – Meets all tagout requirements of this chapter.
     
    – Includes additional safety measures to provide the same level of safety as a lockout system.
    Note:
    Additional safety measures used with the tagout system to provide protection equal to a lockout system could include actions such as:
     
    • Removing part of the isolating circuit.
     
    • Blocking a controlling switch.
     
    • Opening an extra disconnecting device.
     
    • Removing a valve handle.
    You must:
    • Use a tagout system if an energy-isolating device cannot be locked out.
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 04-15-105, § 296-803-50005, filed 7/20/04, effective 11/1/04.]
RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 04-15-105, § 296-803-50005, filed 7/20/04, effective 11/1/04.