Washington Administrative Code (Last Updated: November 23, 2016) |
Title 296. Labor and Industries, Department of |
Chapter 296-803. Lockout/tagout (control of hazardous energy). |
Section 296-803-50005. Use energy control procedures.
Latest version.
- You must:• Use energy control procedures to protect employees servicing or maintaining machines and equipment from potentially hazardous energy.• Use a lockout system if an energy-isolating device can be locked out.Exemption:A tagout system may be used instead of a lockout system if it meets all of the following:• The tagout device is attached where you would have put the lockout device.• The tagout system provides the same level of employee protection as a lockout system.• You can demonstrate that the tagout system:– Meets all tagout requirements of this chapter.– Includes additional safety measures to provide the same level of safety as a lockout system.Note:Additional safety measures used with the tagout system to provide protection equal to a lockout system could include actions such as:• Removing part of the isolating circuit.• Blocking a controlling switch.• Opening an extra disconnecting device.• Removing a valve handle.You must:• Use a tagout system if an energy-isolating device cannot be locked out.