Section 296-52-69085. Multiple magazines.  


Latest version.
  • (1) Separation distance. When two or more storage magazines are located on the same property, each magazine must comply with the minimum quantity of explosives and separation distance requirements for:
    • Magazines (Table H-21)
    • Inhabited buildings, railways, and highways (Table H-20)
    (2) Distances that do not meet requirements. If the separation distance between two or more magazines is less than the distance required (Table H-21), the magazines must:
    • Be considered one magazine
    AND
    • Comply with the minimum distance requirements for inhabited buildings, railways, and highways (Table H-20)
    (3) Distance of grouped magazines to other magazines. Each magazine in a group must comply with minimum magazine distance requirements (Table H-21) in relation to other magazines not considered part of the group.
    (4) Quantity of explosives.
    (a) Magazine group. The total quantity of explosives stored in a magazine group (two or more) must:
    • Be considered one magazine
    • Not exceed the requirements of Table H-21 for one magazine
    (b) Detonator magazine. The quantity of explosives contained in a detonator magazine takes precedence over the minimum magazine distance requirements (Table H-21) when determining the separation distance required between a detonator magazine and magazines that contain other types of explosives.
    (c) Detonator strength. Strengths of blasting and electric detonators:
    • Up to #8 detonators must be rated as one and one-half pounds of explosives per one thousand detonators
    • Detonators greater than #8 must be computed on the combined weight of explosives.
    [Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-69085, filed 1/23/02, effective 3/1/02.]
RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-69085, filed 1/23/02, effective 3/1/02.