Section 296-307-65202. Make sure the following conditions are met if using alternate entry procedures.  


Latest version.
  • You must:
    • Make sure, when using alternate entry procedures, instead of permit entry procedures, that you have monitoring and inspection data that supports the following:
    – That the only hazard of the permit-required confined space is an actual or potentially hazardous atmosphere.
    – That continuous forced air ventilation alone is all that is needed to maintain the permit-required confined space for safe entry.
    • Make sure an entry to obtain monitoring and inspection data or to eliminate hazards is performed according to WAC 296-307-500, Permit entry procedures.
    • Make sure all documentation produced is available to each affected employee and their authorized representative.
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 05-01-166, § 296-307-65202, filed 12/21/04, effective 4/2/05.]
RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 05-01-166, § 296-307-65202, filed 12/21/04, effective 4/2/05.

Rules

296-307-500,