Section 296-307-48505. What requirements apply to flash welding equipment?
Latest version.
(1) Flash welding machines must have a hood to control flying flash. In cases of high production, where materials may contain a film of oil and where toxic elements and metal fumes are given off, ventilation must be provided according to WAC 296-307-50009 through 296-307-50029.
(2) For the protection of the operators of nearby equipment, fire-resistant curtains or suitable shields must be set up around the machine and in such a manner that the operator's movements are not hampered.