Section 296-307-16149. Carbon monoxide alarms, smoke detectors, and fire extinguishers.  


Latest version.
  • (1) An operator must provide and maintain working carbon monoxide alarms that are:
    (a) Located in each dwelling unit with a sleeping area; and
    (b) Installed in accordance with the manufacturer's recommendations in compliance with the building code, WAC 51-51-0315.
    (2) An operator must provide and maintain working smoke detectors that:
    (a) Are located in each sleeping area;
    (b) Are located on each level of dwelling units with a sleeping area;
    (c) Are located in each cooking facility area;
    (d) Emits a signal when the batteries are low;
    (e) Are placed on the ceiling or wall, but not on the wall above any door; and
    (f) Are in compliance with the building code, WAC 51-51-0314.
    (3) An operator must provide properly working fire extinguishers in dwelling units where occupants sleep if the dwelling unit does not have a second means of emergency egress. Fire extinguishers must be:
    (a) A minimum 2A:10BC;
    (b) Installed and maintained according to the manufacturer's instructions; and
    (c) Installed in accordance with local ordinances, codes and regulations when applicable.
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 15-13-092, § 296-307-16149, filed 6/15/15, effective 1/1/16.]
RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 15-13-092, § 296-307-16149, filed 6/15/15, effective 1/1/16.

Rules

51-51-0315,51-51-0314,