Section 296-304-07011. Use of gear.  


Latest version.
  • (1) Loads shall be safely rigged before being hoisted.
    (2) Plates shall be handled on and off hulls by means of shackles whenever possible. Clips or pads of ample size shall be welded to the plate to receive the shackle pins whenever there are no holes in the plate. When it is not possible to make holes in or to weld pads to the plate, alligator tongs, grab hooks, grab clamps or screw clamps may be used. In such cases special precautions shall be taken to keep employees from under such lifts.
    (3) Tag lines shall be provided on loads likely to swing or to need guidance.
    (4) When slings are secured to eyebolts, the slings shall be so arranged, using spreaders if necessary, that the pull is within 20 degrees of the axis of the bolt.
    (5) Slings shall be padded by means of wood blocks or other suitable material where they pass over sharp edges or corners of loads so as to prevent cutting or kinking.
    (6) Skips shall be rigged to be handled by not less than 3 legged bridles, and all legs shall always be used. When open end skips are used, means shall be taken to prevent the contents from falling.
    (7) Loose ends of idle legs of slings in use shall be hung on the hook.
    (8) Employees shall not be permitted to ride the hook or the load.
    (9) Loads (tools, equipment or other materials) shall not be swung or suspended over the heads of employees.
    (10) Pieces of equipment or structure susceptible to falling or dislodgement shall be secured or removed as early as possible.
    (11) An individual who is familiar with the signal code in use shall be assigned to act as a signalman when the hoist operator cannot see the load being handled. Communications shall be made by means of clear and distinct visual or auditory signals except that verbal signals shall not be permitted.
    (12) Pallets, when used, shall be of such material and construction and so maintained as to safely support and carry the loads being handled on them.
    (13) A section of hatch through which materials or equipment are being raised, lowered, moved, or otherwise shifted manually or by a crane, winch, hoist, or derrick, shall be completely opened. The beam or pontoon left in place adjacent to an opening shall be sufficiently lashed, locked or otherwise secured to prevent it from moving so that it cannot be displaced by accident.
    (14) Hatches shall not be opened or closed while employees are in the square of the hatch below.
    (15) Before loads or empty lifting gear are raised, lowered, or swung, clear and sufficient advance warning shall be given to employees in the vicinity of such operations.
    (16) At no time shall an employee be permitted to place himself in hazardous position between a swinging load and a fixed object.
    TABLE E-1
    DIMENSIONS AND SPACING OF WOOD
    INDEPENDENT-POLE SCAFFOLD MEMBERS
    TABLE E-2
    SPECIFICATIONS FOR SIDE RAILS OF LADDERS
    TABLE E-3
    SPECIFICATIONS FOR THE CONSTRUCTION OF HORSES
    TABLE E-4
    SAFE CENTER LOADS FOR SCAFFOLD PLANK
    OF 1,100 POUNDS FIBRE STRESS
    [Codification note: The graphic presentation of this table has been varied in order that it would fall within the printing specifications for the Washington Administrative Code. The following table had lumber dimensions in the table heading typed in vertically across the page while the remainder of the table was typed horizontally on the page. The "Span in Feet" materials (6 through 16) which ran top to bottom has been switched to run left to right on the page. The "Lumber dimensions in inches" which ran left to right on the page has been switched to run top to bottom on the page.]
    TABLE G-1
    NUMBER AND SPACING OF U-BOLT WIRE
    ROPE CLIPS
    TABLE G-2
    MAXIMUM ALLOWABLE WEAR AT
    ANY POINT OF LINK
    [Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW. WSR 12-24-071, § 296-304-07011, filed 12/4/12, effective 1/4/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 03-04-099, § 296-304-07011, filed 2/4/03, effective 8/1/03; Order 74-25, § 296-304-07011, filed 5/7/74.]
RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW. WSR 12-24-071, § 296-304-07011, filed 12/4/12, effective 1/4/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 03-04-099, § 296-304-07011, filed 2/4/03, effective 8/1/03; Order 74-25, § 296-304-07011, filed 5/7/74.