Section 296-303-02007. Miscellaneous machines and equipment.  


Latest version.
  • (1) Sewing machine. Each sewing machine shall be equipped with a guard permanently attached to the machine, so that the operator's fingers cannot pass under the needle. It shall be of such form that the needle can be conveniently threaded without removing the guard. This requirement will not apply to domestic-type sewing machines having a presser-foot which is in the "down" position during operation of the machine.
    (2) Exhaust or ventilating fans. Each exhaust or ventilating fan within seven feet of the floor or working platform shall be completely covered with wire mesh of not less than No. 16 gauge, and with openings that will reject a ball one-half inch in diameter.
    (3) Steam pipes.
    (a) All steam pipes that are within seven feet of the floor or working platform, and with which the worker may come into contact, shall be insulated or covered with a heat-resistive material or shall be guarded to prevent direct contact with the worker.
    (b) Where pressure-reducing valves are used, one or more relief or safety valves shall be provided on the low-pressure side of the reducing valve, in case the piping or equipment on the low-pressure side does not meet the requirements for full initial pressure. The relief or safety valve shall be located adjacent to, or as close as possible to, the reducing valve. Relief and safety valves vented to the atmosphere shall be so constructed as to prevent injury or damage caused by fluid escaping from relief or safety valves. The vents shall be of ample size and as short and direct as possible. The combined discharge capacity of the relief valves shall be such that the pressure rating of the lower-pressure piping and equipment will not be exceeded if the reducing valve sticks or fails to open.
    [Statutory Authority: Chapter 49.17 RCW. WSR 89-11-035 (Order 89-03), § 296-303-02007, filed 5/15/89, effective 6/30/89; Order 74-18, § 296-303-02007, filed 5/6/74.]
Chapter 49.17 RCW. WSR 89-11-035 (Order 89-03), § 296-303-02007, filed 5/15/89, effective 6/30/89; Order 74-18, § 296-303-02007, filed 5/6/74.