Washington Administrative Code (Last Updated: November 23, 2016) |
Title 296. Labor and Industries, Department of |
Chapter 296-150V. Conversion vendor units and medical units. |
Section 296-150V-1400. What are the gas piping hanger and support requirements for a conversion vendor unit or medical unit?
Latest version.
- (1) All gas piping must be adequately supported by galvanized or equivalently protected metal straps or hangers at intervals of not more than 4 feet, except where adequate support and protection is provided by structural members.(2) Gas pipe supply connections must be rigidly anchored to a structural member within 6 inches of the supply connections.[Statutory Authority: Chapter 43.22 RCW. WSR 99-18-069, § 296-150V-1400, filed 8/31/99, effective 10/1/99.]
Chapter 43.22 RCW. WSR 99-18-069, § 296-150V-1400, filed 8/31/99, effective 10/1/99.