Section 296-150V-0930. When are structural load tests or structural calculations required?
Latest version.
- (1) A structural analysis is required when a unit has a concentrated floor load of 500 pounds or more in a 16 square feet or less area.(2) The structural load test can be used as an alternative.(a) A structural assembly tested for qualification must sustain the design dead load plus the superimposed design live loads for vendor units and medical units assembly.(b) An assembly failure is defined as a rupture, fracture, or residual deflection which is greater than the limits.Note:We will provide test procedure forms upon request.[Statutory Authority: Chapter 43.22 RCW. WSR 99-18-069, § 296-150V-0930, filed 8/31/99, effective 10/1/99.]