Section 296-150C-1210. Table: Number of ties required per side of commercial coach.  


Latest version.
  • NUMBER OF TIES REQUIRED PER SIDE OF
    COMMERCIAL COACH
    Note:
    This table is based on a minimum working load per anchor of three thousand one hundred fifty pounds with a fifty percent overload (four thousand seven hundred twenty-five pounds total).
    (1) Double-width commercial coaches require only the diagonal ties specified, and these must be placed along the outer side walls;
    (2) Length of commercial coach (as used in this table) means length excluding draw bar;
    (3) Diagonal ties in this method must deviate at least forty degrees from a vertical direction; or
    (4) The number of ties required can be designed by a professional engineer.
    [Statutory Authority: RCW 43.22.340, [43.22.]355, [43.22.]360, [43.22.]432, [43.22.]440 and [43.22.]480. WSR 96-21-146, § 296-150C-1210, filed 10/23/96, effective 11/25/96.]
RCW 43.22.340, [43.22.]355, [43.22.]360, [43.22.]432, [43.22.]440 and [43.22.]480. WSR 96-21-146, § 296-150C-1210, filed 10/23/96, effective 11/25/96.