Washington Administrative Code (Last Updated: November 23, 2016) |
Title 246. Health, Department of |
Chapter 246-358. Temporary worker housing. |
Section 246-358-080. Carbon monoxide alarms, smoke detectors, and fire extinguishers.
Latest version.
- (1) An operator shall provide and maintain working carbon monoxide alarms that are:(a) Located in each dwelling unit with a sleeping area; and(b) Installed in accordance with the manufacturer's recommendations and in compliance with the building code, WAC 51-51-0315.(2) An operator shall provide and maintain working smoke detectors that:(a) Are located in each sleeping area;(b) Are located on each level of dwelling units with a sleeping area;(c) Are located in each cooking facility area;(d) Emits a signal when the batteries are low;(e) Are placed on the ceiling or wall, but not on the wall above any door; and(f) Are in compliance with the manufacturer's recommendations and the building code, WAC 51-51-0314.(3) An operator shall provide properly working fire extinguishers in dwelling units where occupants sleep if the dwelling unit does not have a second means of emergency egress. Fire extinguishers must be:(a) A minimum 2A:10BC;(b) Installed and maintained according to the manufacturer's instructions;(c) Installed in accordance with local ordinances, codes, and regulations when applicable.
Rules
51-51-0315,51-51-0314,