Washington Administrative Code (Last Updated: November 23, 2016) |
Title 246. Health, Department of |
Chapter 246-272C. On-site sewage system tanks. |
Section 246-272C-0240. Additional requirements for pump tanks.
Latest version.
- (1) A sanitary tee or baffle is required when effluent is pumped into the pump tank.(2) The sanitary tee or baffle for a pump tank must meet the following requirements:(a) The inlet sanitary tee or baffle must be installed on the inlet of the pump tank; and(b) The inlet sanitary tee or baffle must extend into the tank a minimum of eight inches below the invert elevation of the inlet pipe.[Statutory Authority: RCW 43.20.050 (2) and (3). WSR 09-23-119, § 246-272C-0240, filed 11/18/09, effective 12/19/09.]
RCW 43.20.050 (2) and (3). WSR 09-23-119, § 246-272C-0240, filed 11/18/09, effective 12/19/09.