Section 173-182-330. Planning standards for in situ burning.  


Latest version.
  • (1) Based on the NWACP, plan holders operating in areas where in situ burning has an expedited approval process must plan for the use of in situ burning.
    (2) The plan holder must identify the locations of two fire booms, air monitoring equipment, igniters and aircraft or vessels to be used to deploy the igniters.
    (3) The fire booms must be five hundred feet in length each and have an additional one thousand feet of conventional boom, tow bridles and work boats capable of towing the boom for burning operations.
    (4) The plan holder must describe the methods of transporting the equipment to a staging area, and appropriate aircraft or vessels to monitor its effectiveness at the scene of an oil discharge.
    (5) These resources must be capable of being on-scene within twelve hours of spill notification.
    [Statutory Authority: Chapters 88.46, 90.48, 90.56 RCW, and 2011 c 122. WSR 13-01-054 (Order 11-06), § 173-182-330, filed 12/14/12, effective 1/14/13. Statutory Authority: Chapters 88.46, 90.56, and 90.48 RCW. WSR 06-20-035 (Order 00-03), § 173-182-330, filed 9/25/06, effective 10/26/06.]
Chapters 88.46, 90.48, 90.56 RCW, and 2011 c 122. WSR 13-01-054 (Order 11-06), § 173-182-330, filed 12/14/12, effective 1/14/13. Statutory Authority: Chapters 88.46, 90.56, and 90.48 RCW. WSR 06-20-035 (Order 00-03), § 173-182-330, filed 9/25/06, effective 10/26/06.